<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>شرکت ملی پالایش و پخش فرآورده های نفتی ایران</PublisherName>
				<JournalTitle>نشریه علمی فرآیند نو</JournalTitle>
				<Issn>1735-6466</Issn>
				<Volume>20</Volume>
				<Issue>91</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Studying the Decrease in CO2 Emission and Energy Consumption of the Process of Light Naphtha Hydrotreating</ArticleTitle>
<VernacularTitle>بررسی کاهش انتشار CO₂ و مصرف انرژی فرایند تصفیه هیدروژنی نفتای سبک</VernacularTitle>
			<FirstPage>5</FirstPage>
			<LastPage>18</LastPage>
			<ELocationID EIdType="pii">730084</ELocationID>
			
<ELocationID EIdType="doi">10.22034/farayandno.2025.2068507.2008</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مهدی</FirstName>
					<LastName>محمدی رهقی</LastName>
<Affiliation>دانشجوی دکتری مهندسی شیمی، دانشکده مهندسی، دانشگاه کاشان، کاشان</Affiliation>

</Author>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>حیاتی آشتیانی</LastName>
<Affiliation>استادیار مهندسی شیمی، دانشکده مهندسی، دانشگاه کاشان، کاشان</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>08</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		    <Abstract>Simultaneously reducing energy consumption and environmental pollutants in refining industries has become a major challenge and priority. Pinch Technology is a design method for optimizing energy consumption to specify the process optimum condition for achieving this purpose. This study aims to optimize the economic and environmental performance of a Light Naphtha Hydrotreating unit using the pinch analysis method. For this purpose, three modifications were made based o­n different minimum approach temperatures of 8, 12, and 16 °C. These modifications were evaluated from the perspectives of energy consumption, carbon dioxide emissions, and economic costs. The modification based on a minimum approach temperature of 12 °C was selected as the optimum option. This retrofitting resulted in 40% reductions in energy consumption, 41% in carbon dioxide emissions, and 41% increase in operating costs with a payback time of approximately 3.59 years.</Abstract>
			<OtherAbstract Language="FA">کاهش همزمان مصرف انرژی و آلاینده های محیط زیستی در صنایع پالایشگاهی، به یک چالش و اولویت مهم تبدیل شده است. فناوری پینچ روش طراحی برای بررسی امکان کاهش مصرف انرژی است که حالت بهینه فرایند را برای دست یابی به این هدف مشخص می‌کند. این مطالعه با هدف بهینه‌سازی اقتصادی و محیط زیستی واحد تصفیه هیدروژنی نفتای سبک با بکارگیری روش تحلیل پینچ انجام شده است. بدین منظور، سه طرح اصلاحی مبتنی بر مقادیر مختلف اختلاف دمای کمینه برابر با 8، 12 و °C 16 پیشنهاد شد و از دیدگاه مصرف انرژی، انتشار دی اکسید کربن و هزینه‌های اقتصادی ارزیابی شدند که طرح مبتنی بر اختلاف دمای کمینه برابر با °C 12به ‌عنوان گزینه بهینه انتخاب شد. این طرح اصلاحی کاهش های 40% در مصرف انرژی، 41% در انتشار دی اکسید کربن و 41% و افزایش در هزینه‌های عملیاتی با زمان بازگشت سرمایه حدود 3/59 سال به همراه داشت.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">انتشار دی اکسید کربن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شبکه مبدل های حرارتی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">هزینه های کلی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">طرح اصلاحی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مصرف انرژی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.farayandno.ir/article_730084_af7d150bdb75180f2f4b7604e8d4baf6.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>شرکت ملی پالایش و پخش فرآورده های نفتی ایران</PublisherName>
				<JournalTitle>نشریه علمی فرآیند نو</JournalTitle>
				<Issn>1735-6466</Issn>
				<Volume>20</Volume>
				<Issue>91</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Laboratory study of CO2 removal from gas mixture using membrane contactor technology</ArticleTitle>
<VernacularTitle>مطالعه آزمایشگاهی حذف CO2 از مخلوط گازی با استفاده از فناوری تماس-دهنده‌های غشایی</VernacularTitle>
			<FirstPage>21</FirstPage>
			<LastPage>36</LastPage>
			<ELocationID EIdType="pii">733059</ELocationID>
			
<ELocationID EIdType="doi">10.22034/farayandno.2025.2070418.2014</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>پریا</FirstName>
					<LastName>امیرعابدی</LastName>
<Affiliation>گروه مهندسی شیمی، دانشکده فنی و مهندسی، دانشگاه صنعتی خاتم الانبیاء (ص) بهبهان، بهبهان، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>08</Month>
					<Day>31</Day>
				</PubDate>
			</History>
		    <Abstract>Membrane contactors are one of the effective technologies for reducing CO2 emissions in the environment. Accordingly, in the present study, membrane contactors containing polyvinyl chloride/calcium carbonate membranes were fabricated to remove CO2 from a gaseous feed with a composition similar to the flue gas composition of a reference cement plant. The average results of contact angle measurements for pure and nanocomposite membranes were 78° and 92°, respectively, indicating an increase in the hydrophobicity of the membranes due to the presence of nanoparticles. Also, the results showed that increasing the gas velocity had a negative effect on the absorption efficiency, but on the contrary, increasing the operating pressure and absorbent velocity increased the absorption efficiency. In addition, analysis of the CO2 absorption results showed that at an absorbent velocity of (200 ml/min), the nanocomposite membrane had the highest CO2 absorption efficiency (88%) and the highest absorption flux (2.17 × 10-3 mol/m2s).</Abstract>
			<OtherAbstract Language="FA">تماس­­ دهنده ­های غشایی یکی از فناوری ­های موثر در جهت کاهش آلودگی­ های حاصل از انتشار CO2 در محیط­زیست هستند. بر این اساس در پژوهش حاضر، تماس­ دهنده های غشایی حاوی غشاهای پلی ­ونیل­ کلراید/کربنات کلسیم، جهت حذف  CO2از خوراک گازی با ترکیبی مشابه با ترکیب درصد گاز دودکش یک کارخانه سیمان مرجع ساخته شدند. میانگین نتایج حاصل از اندازه­ گیری زاویه تماس غشاهای خالص و نانوکامپوزیتی به ترتیب °78 و °92 بدست آمد که حاکی از افزایش قدرت آبگریزی غشاها به دلیل حضور نانوذرات بود. همچنین، نتایج نشان داد که افزایش سرعت گاز تأثیر منفی بر روی بازده جذب داشته، ولی در مقابل، افزایش فشار عملیاتی و سرعت جاذب بازده جذب را افزایش دادند. بعلاوه، تحلیل نتایج حاصل از جذب CO2 نشان داد که در سرعت جاذب ((ml/min 200، غشای نانوکامپوزیتی بیشترین بازده جذب CO2 (88%) و بیشترین شار جذب (mol/m2s)) 3-10 × 2/17) را دارا می­باشد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">CO2، کارخانه سیمان، تماس&amp;shy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">؛ ؛ ؛ ؛ دهنده &amp;shy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">؛ ؛ ؛ ؛ های غشایی، بازده جذب</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.farayandno.ir/article_733059_c771d5425d7e14f110dc653ea40fb115.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>شرکت ملی پالایش و پخش فرآورده های نفتی ایران</PublisherName>
				<JournalTitle>نشریه علمی فرآیند نو</JournalTitle>
				<Issn>1735-6466</Issn>
				<Volume>20</Volume>
				<Issue>91</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Thermodynamic and Environmental Assessment of a Tri-Generation Power Plant Utilizing Municipal Solid Waste</ArticleTitle>
<VernacularTitle>تحلیل ترمودینامیکی و زیست محیطی نیروگاه تولید سه منظوره با استفاده از زباله های جامد شهری</VernacularTitle>
			<FirstPage>37</FirstPage>
			<LastPage>54</LastPage>
			<ELocationID EIdType="pii">733056</ELocationID>
			
<ELocationID EIdType="doi">10.22034/farayandno.2025.2065516.2002</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>رضا</FirstName>
					<LastName>باقری</LastName>
<Affiliation>دانش آموخته کارشناسی ارشد مهندسی فرآیند، دانشکده مهندسی شیمی، دانشگاه تربیت مدرس، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>پرویز</FirstName>
					<LastName>درویشی</LastName>
<Affiliation>دانشیار مهندسی شیمی، عضو هیات علمی دانشکده مهندسی، دانشگاه یاسوج، یاسوج، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-0784-0470</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>07</Month>
					<Day>11</Day>
				</PubDate>
			</History>
		    <Abstract>In this study, a detailed thermodynamic and CO₂ emission analysis was carried out for an integrated biomass-fueled tri-generation system that simultaneously produces electricity, desalinated water, and cooling. The main novelty of the new proposed configuration lies in its combined use of urban solid waste as fuel to generate three useful energy outputs, improving overall efficiency and reducing CO₂ emissions compared with previous studies. According to the baseline simulation, the system can generate 4,994 kW of net electrical power, 1,034 kW of cooling, and 11,960 kg/h of desalinated water with a 33.28% recovery rate. The overall energy and electrical efficiencies are 73.82 and 39.92%, respectively, with a CO₂ footprint of only 0.2 kg CO₂/kWh. Parametric analyses indicate that optimizing the gas turbine inlet temperature and the Organic Rankine Cycle pressure further enhances performance. Overall, the system offers a sustainable and practical solution for coastal, island, and small industrial or residential applications.</Abstract>
			<OtherAbstract Language="FA">در این مطالعه، تحلیل جامع ترمودینامیکی و انتشار دی‌اکسید کربن برای یک سامانه سه‌منظوره یکپارچه با سوخت زیست‌توده انجام شد. نوآوری اصلی پژوهش، ارائه یک پیکربندی جدید جهت یکپارچه‌سازی هم‌زمان سه نوع خروجی انرژی با استفاده از زباله‌های جامد شهری به عنوان سوخت است که باعث افزایش بازده کلی و کاهش انتشار دی‌اکسید کربن نسبت به مطالعات پیشین می‌شود. بر اساس شبیه‌سازی حالت پایه، سیستم قادر است 4994 کیلووات توان الکتریکی خالص، 1034 کیلووات سرمایش معادل و kg/h 11960 آب شیرین با نرخ بازیافت 33/28 درصد تولید کند. بازده کلی انرژی و بازده الکتریکی به ترتیب 73/82 و 39/92 درصد و ردپای کربن معادل kg CO₂/kWh 0.2 است. تحلیل‌های پارامتری نشان می‌دهد افزایش دمای ورودی توربین گازی و فشار سیکل ارگانیک رانکین موجب بهبود عملکرد انرژی و کاهش انتشار می‌شود. نتایج، پتانسیل بالای این سامانه را به عنوان راهکاری پایدار برای مناطق ساحلی و جوامع کوچک تا متوسط تأیید می‌کند.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">زیست توده</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">راندمان ترمودینامیکی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تبرید جذبی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تولید سه‌گانه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نمک‌زدایی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.farayandno.ir/article_733056_e41a85a3b3313519146041378173534e.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>شرکت ملی پالایش و پخش فرآورده های نفتی ایران</PublisherName>
				<JournalTitle>نشریه علمی فرآیند نو</JournalTitle>
				<Issn>1735-6466</Issn>
				<Volume>20</Volume>
				<Issue>91</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Design of a hydrogen and water production system based on coffee husk biomass fuel</ArticleTitle>
<VernacularTitle>طراحی یک سیستم تولید هیدروژن و آب بر مبنای سوخت زیست توده پوسته قهوه</VernacularTitle>
			<FirstPage>55</FirstPage>
			<LastPage>72</LastPage>
			<ELocationID EIdType="pii">733055</ELocationID>
			
<ELocationID EIdType="doi">10.22034/farayandno.2025.2068451.2009</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>امیرحسین</FirstName>
					<LastName>شیری</LastName>
<Affiliation>بخش مهندسی فرآیند، دانشکده مهندسی شیمی، دانشگاه تربیت مدرس، تهران</Affiliation>

</Author>
<Author>
					<FirstName>محمد</FirstName>
					<LastName>بنیادی</LastName>
<Affiliation>دانشیار گروه مهندسی شیمی، دانشکده فنی و مهندسی، دانشگاه یاسوج، یاسوج</Affiliation>
<Identifier Source="ORCID">0000-0002-5346-5720</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>07</Month>
					<Day>09</Day>
				</PubDate>
			</History>
		    <Abstract>In this work, an integrated system utilizing coffee husk biomass combustion and liquefied natural gas cooling for the simultaneous production of freshwater, hydrogen, electrical power, hot water, and cold water has been investigated and analyzed. This novel process encompasses biomass combustion, liquefied gas cooling, organic Rankine cycle, ammonia Rankine cycle, multi-effect desalination, and an ion exchange membrane electrolysis. Thermodynamic analysis using energy and exergy analysis, as well as parametric analysis, has been performed on the proposed system. The results show that the system has a thermal efficiency of 29.9%, an exergy efficiency of 14.38% and an electrical efficiency of 16.91%. The effect of changing the operating conditions of the system on the system performance has been evaluated. This system is capable of producing 5053 kW of cooling power, 850 kW of heating power, 8391 kW of electrical power, 12.1 kg/h of hydrogen, and 1569 kg/h of fresh water.</Abstract>
			<OtherAbstract Language="FA">در این مطالعه، یک سامانه یکپارچه با استفاده از احتراق زیست توده پوسته قهوه و سرمایش گاز طبیعی مایع برای تولید همزمان آب شیرین، هیدروژن، توان الکتریکی، آب گرم و آب سرد، مورد بررسی قرار گرفته است. این فرآیند نوین شامل احتراق زیست توده، بهره‌گیری از سرمایش گاز طبیعی مایع شده، چرخه رانکین آلی، چرخه رانکین آمونیاک، نمک‌زدایی چنداثره و الکترولایزر غشای تبادل یونی می‌باشد. تحلیل ترمودینامیکی با استفاده از آنالیز انرژی و اکسرژی، و نیز تحلیل پارامتری بر روی سامانه پیشنهادی صورت گرفته است. نتایج نشان می‌دهد که سامانه دارای بازده حرارتی 29/9 درصد، بازده اکسرژی 14/38 درصد و بازده الکتریکی 16/91 درصد است. همچنین، اثر تغییر شرایط عملیاتی سامانه بر عملکرد آن مورد ارزیابی قرار گرفته است. این سامانه قادر است 5053 کیلووات توان سرمایشی، 850 کیلووات توان گرمایشی، 8391 کیلووات توان الکتریکی، 12/1 کیلوگرم بر ساعت هیدروژن و 1569 کیلوگرم بر ساعت آب شیرین تولید کند.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">زیست توده</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سامانه یکپارچه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نمک‌زدایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تولید هیدروژن</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آنالیز اکسرژی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.farayandno.ir/article_733055_160ce723e7da87417a4851d973b7a5a3.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>شرکت ملی پالایش و پخش فرآورده های نفتی ایران</PublisherName>
				<JournalTitle>نشریه علمی فرآیند نو</JournalTitle>
				<Issn>1735-6466</Issn>
				<Volume>20</Volume>
				<Issue>91</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Review of Standards, Localization and Performance Improvement of Pulse Air Inlet Filters for Gas Turbines</ArticleTitle>
<VernacularTitle>بررسی استاندارد، بومی‌سازی و بهسازی عملکرد فیلتر ورودی هوای پالس توربین گاز</VernacularTitle>
			<FirstPage>73</FirstPage>
			<LastPage>86</LastPage>
			<ELocationID EIdType="pii">733057</ELocationID>
			
<ELocationID EIdType="doi">10.22034/farayandno.2025.2074684.2023</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>علیرضا</FirstName>
					<LastName>رحیمی</LastName>
<Affiliation>کارشناس ارشد مهندسی مکانیک، واحد مهندسی معکوس و ساخت کالا، پتروشیمی بوشهر، عسلویه، ایران</Affiliation>
<Identifier Source="ORCID">0009-0008-0122-909X</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>08</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		    <Abstract>This study investigates the standards, design principles, and localization process of a pulse air inlet filter for gas turbines, focusing on a successful case at Bushehr Petrochemical Complex. The main objective was to develop a domestically manufactured filter with performance equivalent to the Camfil reference while reducing operational costs. Localization involved extracting the technical specifications of the original filter and applying an electrospun nanofiber coating onto commercial filter media. Experimental results showed that the localized filter achieved the F9 filtration class while reducing total pressure drop from 422 Pa to 121 Pa—approximately a 71% improvement in airflow resistance. This reduction directly decreases power consumption and enhances turbine efficiency. The nanofiber layer improved surface filtration, preventing deep clogging within the media. The localized filter demonstrated stable, economical, and reliable performance, offering lower manufacturing costs and easier accessibility, making it a suitable replacement for the original imported unit.</Abstract>
			<OtherAbstract Language="FA">پژوهش حاضر به بررسی استانداردها، اصول طراحی و فرآیند بومی‌سازی فیلتر ورودی هوای پالس توربین گاز، با تمرکز بر نمونه‌ای موفق در پتروشیمی بوشهر می‌پردازد. هدف اصلی، ساخت نمونه داخلی با عملکرد معادل فیلتر مرجع شرکت Camfil و کاهش هزینه‌های عملیاتی است. فرآیند بومی‌سازی با استخراج مشخصه‌های فنی فیلتر اصلی و به‌کارگیری پوشش نانوالیاف بر بستر تجاری بازار انجام شد. نتایج آزمایشگاهی نشان داد فیلتر بومی‌سازی‌شده ضمن دستیابی به کلاس فیلتراسیون F9، افت فشار را از ۴۲۲ به ۱۲۱ پاسکال کاهش داده و حدود ۷۱ درصد بهبود در مقاومت جریان هوا ایجاد کرده است. این ویژگی موجب کاهش مصرف توان و افزایش بازدهی توربین می‌شود. لایه نانوالیاف با تقویت فیلتراسیون سطحی، مانع انسداد داخلی بستر شده است. فیلتر بومی‌سازی‌شده با عملکردی پایدار، اقتصادی و قابل اتکا، ضمن کاهش هزینه ساخت و فراهم‌سازی دسترسی آسان‌تر به محصول، جایگزینی مناسب برای نمونه اصلی محسوب می‌شود.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Gas Turbine Pulse Air Intake Filter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">localization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Filtration Efficiency</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Nanofiber Coating</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Self-cleaning</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.farayandno.ir/article_733057_af5dbad6137a2206e25df8c7e40348ec.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>شرکت ملی پالایش و پخش فرآورده های نفتی ایران</PublisherName>
				<JournalTitle>نشریه علمی فرآیند نو</JournalTitle>
				<Issn>1735-6466</Issn>
				<Volume>20</Volume>
				<Issue>91</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>11</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Technical-economic justification of replacing clarifier processes with chemical injections to improve cooling tower performance in a selected thermal power plant</ArticleTitle>
<VernacularTitle>توجیه فنی- اقتصادی جایگزینی فرایندهای کلاریفایر با اعمال تزریقات شیمیایی بهبود دهنده عملکرد برج خنک‌کن در یک نیروگاه حرارتی منتخب</VernacularTitle>
			<FirstPage>87</FirstPage>
			<LastPage>104</LastPage>
			<ELocationID EIdType="pii">733058</ELocationID>
			
<ELocationID EIdType="doi">10.22034/farayandno.2025.2068814.2010</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مریم</FirstName>
					<LastName>چینی ساز</LastName>
<Affiliation>گروه شیمی، دانشکده علوم، دانشگاه بین المللی امام خمینی (ره)، قزوین، ایران</Affiliation>

</Author>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>سلیمانی</LastName>
<Affiliation>گروه شیمی، دانشکده علوم، دانشگاه بین المللی امام خمینی (ره)، قزوین، ایران</Affiliation>

</Author>
<Author>
					<FirstName>محسن</FirstName>
					<LastName>اسماعیل پور</LastName>
<Affiliation>گروه پژوهشی شیمی و فرآیند، پژوهشگاه نیرو، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>مجید</FirstName>
					<LastName>قهرمان افشار</LastName>
<Affiliation>گروه پژوهشی شیمی و فرآیند، پژوهشگاه نیرو، تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-6208-0654</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>08</Month>
					<Day>13</Day>
				</PubDate>
			</History>
		    <Abstract>In this study, a thermal power plant is studied from the point of view of performance and costs of clarifier-related processes on the corrosion and fouling rate of the condenser. This power plant has four cooling towers that are responsible for cooling the condensate water returned from the condenser. Examination of the results of raw water and soft water after the clarifier (injection of FeCl3 and CaOH) in recent years shows that the alkalinity and hardness levels before and after the clarifier have not decreased significantly. In the current situation, chemical control with the previous chemical regime leads to an increase in the corrosion and sedimentation rate due to the increase in the conductivity of the clarifier supply water. To tackle this issue, a new chemical regime based on the elimination of clarifier processes and the use of corrosion and sedimentation inhibitor compounds are proposed here. In order to investigate the effect of the new chemical regime on the condenser performance, investigation is conducted through coupon monitoring and chemical factor monitoring. The results of the condenser coupon monitoring indicate that the condenser corrosion rate is reduced by six times by applying the new chemical regime. Moreover, the rate of destruction of the wooden structure of the cooling tower in the control unit is 1.5 times higher than in the test unit. On the other hand, based on coupon monitoring results, the rate of sedimentation in the control tower is 1.7 times higher than that of the test cooling tower. Overall results indicate that the corrosion and sedimentation rates are much more effective with the elimination of clarifier processes and the application of the new chemical regime than with the previous regime. Therefore, it is recommended to eleminate the clarifier processes and use antiscalant and anti-corrosion for other thermal power plants whose supply water has been facing a decline in quality and increased conductivity in recent years.</Abstract>
			<OtherAbstract Language="FA">در این تحقیق یک نیروگاه حرارتی از نظر عملکرد و هزینه‌های فرایندهای مربوط‌به کلاریفایر بر‌روی نرخ خوردگی و رسوبگذاری کندانسور مورد‌مطالعه قرار می‌گیرد. نیروگاه مورد مطالعه دارای چهار برج خنک­کن تر است که مسئولیت خنک­کاری آب کندانس برگشتی از کندانسور را برعهده دارد. بررسی نتایج آزمون­های پایش آب خام و آب نرم بعد از کلاریفایر (تزریق آهک و کلروفریک) در سالیان اخیر نشان می­دهد که میزان قلیائیت و سختی قبل و بعد از کلاریفایر کاهش قابل‌توجهی نداشته است. در شرایط کنونی به علت افزایش هدایت آب تأمینی کلاریفایر، کنترل خوردگی و رسوبگذاری با رژیم شیمیایی سابق منجر‌به افزایش نرخ خوردگی و رسوبگذاری می­گردد. با توجه به عدم‌پاسخگویی عملکرد کلاریفایر، رژیم شیمیایی نوین بر‌پایه حذف فرایندهای کلاریفایر و استفاده از ترکیبات بازدارنده خوردگی و رسوبگذاری در دستور کار قرار می­گیرد. به‌منظور بررسی تأثیر رژیم نوین شیمیایی بر عملکرد کندانسور مطالعات از طریق پایش کوپن­گذاری و عوامل شیمیایی دنبال می­گردد. نتایج کوپن­گذاری از جنس کندانسور حاکی از آن‌است که میزان خوردگی کندانسور با اعمال رژیم نوین شیمیایی به‌میزان شش‌برابر کاهش می­یابد. همچنین میزان تخریب ساختار چوبی برج خنک­کن در واحد کنترل نسبت به واحد آزمون 5/1‌برابر بیشتر است. از سوی دیگر براساس نتایج کوپن­گذاری، میزان رسوبگذاری در برج کنترل به‌میزان 7/1‌برابر بیشتر از برج خنک‌کن آزمون می­باشد. مجموع نتایج حاکی از آن‌است که نرخ خوردگی و رسوبگذاری با حذف فرایندهای کلاریفایر و اعمال رژیم نوین شیمیایی به‌مراتب مؤثرتر از رژیم پیشین است. لذا تغییر حذف فرایندهای کلاریفایر و کاربرد بازدارنده خوردگی و رسوبگذاری برای سایر نیروگاه­های حرارتی که آب تأمینی آنها در سال‌های اخیر با کاهش کیفیت و افزایش هدایت روبروست توصیه می­گردد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">نیروگاه حرارتی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کلاریفایر</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بازدارنده خوردگی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بازدارنده رسوبگذاری</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">توجیه فنی-اقتصادی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.farayandno.ir/article_733058_b15e29dffbd6f3038ab65a733a136275.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
