[1] F. Dai, Z. Xu, F. Shi, L. Yan, X. Pang and K. Gao, "Mechanical and corrosion behaviors of 17-4PH martensitic stainless steel after 3.5 years of service in nuclear power plant secondary loop environment," Corrosion Science, vol. 270, pp. 114029, 2026.
[2] C. Du , X. Wang , Q. Huang and Y. Zhang, "Corrosion behavior of Cr steel tube in ultra-supercritical power plants under the sulfidation-oxidation coupling effect," Anti-Corrosion Methods and Materials, vol. 73, pp. 544-553, 2026.
[3] M. Shiri, M. Amirjan, D. Rezakhani and S. Naghdali, "Investigation of copper corrosion behavior subjected to power plants’ atmosphere," Materials Today Communications, vol. 49, pp. 114037, 2025.
[4] A. Jahangiri, M.M. Yahyaabadi and A. Sharif, "Exergy and economic analysis of using the flue gas injection system of a combined cycle power plant into the Heller Tower to improve the power plant performance," Journal of Cleaner Production, vol. 233, pp. 695-710, 2019.
[5] C. Shi, Z. Li, Y. Tang, J. Chen, B. Lei, H. An, S.Wang, G. Liu and Y. Shao, "Multi-Factor Coupling Effects on the Electrochemical Corrosion Behavior and Mechanism of 7A04 Aluminum Alloy," Surfaces and Interfaces, In Press, 2026.
[6] M. Hao, H. Tan, W. Yang, D. Yue, L. Gao, Z. Wang and C. He, "Effect of pH on long-term corrosion protection of Zn doped MgAl-LDHs coatings by in situ growth on 5052 aluminum alloy," Surfaces and Interfaces, vol. 64, 2025.
[7] D. Wang, A. Leong, Q. Yang and J. Zhang, "Corrosion behavior of aluminum alloy in simulated nuclear accident environments regarding the chemical effects in GSI-191," Nuclear Engineering and Technology, vol. 54, pp. 4062-4071, 2022.
[8] I.B. Obot, N.O. Obi-egbedi and S.A.Umoren, "The synergistic inhibitive effect and some quantum chemical parameters of 2,3-diaminonaphthalene and iodide ions on the hydrochloric acid corrosion of aluminium," Corrosion Sceince, vol. 51, pp. 276-282, 2009.
[9] G. Williams, A.J. Coleman and H.N. Mc Murray, "Inhibition of Aluminium Alloy AA2024-T3 pitting corrosion by copper complexing compounds,"Electrochimica Acta, vol. 55, pp. 5947-5958, 2010.
[10] S. Safak, B. Duran, A. Yart and G. Turgoglu, "Schiff bases as corrosion inhibitor for aluminium in HCl solution," Corrosion Sceince, vol. 54, pp. 251-259, 2012.
[11] K.D. Ralston, D. Fabijanic and N. Birbilis, "Effect of grain size on corrosion of high purity aluminium," Electrochimica Acta, vol. 56, pp. 1729-1736, 2011.
[12] D. Chen, K. Howe, J. Dallman and B. Letellier, "Corrosion of aluminium in the aqueous chemical environment of a loss-of-coolant accident at a nuclear power plant," Corrosion Sceince, Vol 50, pp. 1046-1057, 2008.
[13] P. Tamara and N. Pvel, "Behavior of aluminium corrosion products in water-steam cycle of power plant," PREPRINT-ICPWS XV, Berlin, pp. 8-11, 2008.
[14] D.S. Abraham, H. Kanagasabapathy and R. John, "Evaluation of Corrosion Behaviour for Aluminium Alloy 7075 in 5% NaCl Solution under Slightly Varying Temperature," Advanced Materials, vol. 984, pp. 557-563, 2014.
[15] P. Lacková, M. Halama and L. Dragošek, "The Corrosion Properties of EN AW 7075 Aluminium Alloy in Power Industry," Materials Science, vol. 811, pp. 83-87, 2015.
[16] J. Xiao, J. Ren, S. Xiao, H. Zhang, J. Chen, Y. Ren, C. Liu and C. Jia, "Corrosion behavior of different alloys in novel chloride molten salts for concentrating solar power plants," Solar Energy Materials and Solar Cells, vol. 286, pp. 113531, 2025.
[18] M. Al-Abed Allah and M. Arroussi, "Osman K. Siddiqui, Muhammad Yusuf, Timothy N. Hunter, Afaque Shams, Ihsan ul Haq Toor, Flow accelerated corrosion in nuclear power plants: a detailed review on mechanisms, mitigation, and management," Engineering Failure Analysis, vol. 183, 2026.
[20] Q. Ma, H. Li, Y. Liu, M. Liu, X. Fu, S. Chu, H. Li and J. Guo, "Facile synthesis of flower-like α-Fe2O3/ZnFe2O4 architectures with self-assembled core-shell nanorods for superior TEA detection," Current Applied Physics, vol. 21, pp.161-169, 2021.
[21] M.S. Lv, G.L. Chen, T. T. Wang, Y.Y. Xin, Z.P. Deng, Y.M. Xu, L.H. Huo and S. Gao, "Willow catkins-assisted synthesis of ZnFe2O4/ZnO hetero-tubes for chemiresistive dibutylamine sensors operated at 130 °C," Sensors and Actuators B: Chemical," vol. 417, pp. 136203, 2024.
[22] Battelle Pacific Northwest Laboratories, Prepared for the Energy Research and Development Administration under Contract, E(45-1), 1830, 1976.
[23] Comprehensive Cycle Chemistry Guidelines for Combined Cycle/Heat Recovery Steam Generators (HRSGs), Technical report, 2013.
[24] M. Chinisaz, M. Soleimani, M. Esmaeilpour and M. Ghahraman Afshar, "Application of novel chemical regimen in a thermal power plants’ cooling tower," Energy Reports, vol. 15, pp.109010, 2026.
[25] A.Yousefpour, M. Mehdizadeh, H. Ghaseminejad, M. Esmaeilpour, N. Abdi, M. Valaee and M. Esmaeilzadeh, "Investigating corrosion caused by improper operation in CWT regime of a combined cycle power plant; Causes and solutions, Energy Equipment and Systems, vol. 13, pp. 35-57, 2025.
[26] M. Ghahraman. Afshar, M. Azimi, N. Habibi, H. Masihi, and M. Esameilpour, "Batch and continuous bleaching regimen in the cooling tower of Montazer Ghaem power plant," Journal of Hazardous Materials Advances, vol. 11, pp. 100339, 2023.